|
Product Details:
Payment & Shipping Terms:
|
Before buying, please read the followings carefully.
Function Features
1.True double-conversion online UPS
A true double conversion UPS will provide clean, high level quality power to fully protect mission-critical devices such as sensitive networks, small computer centers, servers, telecom applications, as well as for industrial applications.
2. Pure sine wave output
With pure sine wave output, guarantees compatibility for all kinds of loads. Its perfect power protection for versatile applications such as networking, telecom and other mission-critical applications.
3. Wide input voltage range (110V-300V)
Mercury series can still provide stable power to connected devices under unstable power environments.
4. 50/60 Hz Frequency Converter Mode
Lock output frequency at 50Hz or 60Hz to suit power sensitive equipments.
5. Output power factor 0.8
Compared to the online UPS in the current market, Mercury series UPS provides better output power factorup to 0.8. It offers higher performance and effciency for critical applications.
6.ECO mode operation for energy saving
Offers efficiency as high as 97% to cut energy usage &cost. UPS power application via static bypass, timely returning to online double conversion when the need arises.
7. Emergency Power Off (EPO) Function
This feature can secure the personnel and equipment in case of fires or other emergencies.
8. USB+RS232+RJ45+SNMP multiple communication for 1-3K models
This feature allows either USB,RS232 or Rj45 communication port to work with SNMP interface simultaneously.
Monitoring Software
• UPS can be connected to the computer via USB or Rs232 interface. So it can be realized LAN monitoring single or many sets of UPS, it also can monitor the other ups which connected to the computer via LAN.
• UPS monitoring software has more than 10 kinds of language for choice.
• Humanized operation interface, which is powerful and can shows the battery voltage, frequency, load, temperature and other data by real-time monitoring through the charts.
• Alarm of different power incident could be set by radio, mobile phone text messages, e-mails and SNMP etc.
Product Pictures
ONLINEUPS
ONLINE UPS
Product catalog
ups
Technical Specification
High Frequency Rack UPS |
||||||||||||||
MODEL |
PHR1101B |
PHR1101 |
PHR1102 |
PHR1103 |
PHR1106 |
PHR1110 |
||||||||
CAPACITY |
1000 VA / 800 W |
2000 VA / 1600 W |
3000 VA / 2400 W |
6000 VA / 4800 W |
10000 VA / 8000 W |
|||||||||
Battery Voltage |
36V |
72V |
72V |
192V |
192V |
|||||||||
Size, D X W X H (mm) |
380 x 438 x 88 |
480x 438 x 88 |
580 x 438 x 88 |
668 x 438 x 88 |
||||||||||
Net Weight (kgs) |
13 |
6.5 |
8.3 |
10 |
15 |
18 |
||||||||
INPUT |
||||||||||||||
Voltage Range |
Low Line Transfer |
160VAC/140VAC/120VAC/110VAC±5% |
110 VAC ± 3 % at 50% Load; 176 VAC ± 3 % at 100% Load |
|||||||||||
Low Line Comeback |
168VAC/148VAC/128VAC/118VAC ± 5 % 0) |
Low Line Loss Voltage + 10V |
||||||||||||
High Line Transfer |
300 VAC ± 5 % |
300 VAC ± 3 % |
||||||||||||
High Line Comeback |
290 VAC ± 5 % |
High Line Loss Voltage - 10V |
||||||||||||
Frequency Range |
40Hz ~ 70 Hz |
46Hz ~ 54 Hz @ 50Hz 56Hz ~ 64 Hz @ 60Hz |
||||||||||||
Phase |
Single phase with ground |
|||||||||||||
Power Factor |
≥ 0.99 @ nominal voltage (input voltage) |
≥ 0.99 at 100% Load |
||||||||||||
OUTPUT |
||||||||||||||
Output voltage |
200/208/220/230/240VAC |
208/220/230/240VAC |
||||||||||||
AC Voltage Regulation |
± 1% (Batt. Mode) |
± 1% |
||||||||||||
Frequency Range (Synchronized Range) |
47Hz ~ 53 Hz @ 50Hz 57Hz ~ 63 Hz @ 60Hz |
46Hz ~ 54 Hz @ 50Hz 56Hz ~ 64 Hz @ 60Hz |
||||||||||||
Frequency Range (Batt. Mode) |
50 Hz ± 0.25 Hz or 60Hz ± 0.3 Hz |
50 Hz ± 0.1 Hz or 60Hz ± 0.1 Hz |
||||||||||||
Overload |
100%~110%:audible warning 110%~130%: UPS shuts down in 60 seconds at battery mode or transfer to bypass when the utility is normal >130%:UPS shuts down immediately at battery mode or transfer to bypass mode when the utility is normal |
AC mode :100%~110%: 10min,110%~130%: 1min,>130% : 1sec Battery mode :100%~110%: 30sec,110%~130%: 10sec,>130% : 1sec |
||||||||||||
Current Crest Ratio |
3:1 max |
|||||||||||||
Harmonic Distortion |
≤ 3 % @ 100% Linear Load; ≤ 6 % @ 100% Non-linear Load |
|||||||||||||
Transfer Time |
AC Mode to Batt. Mode |
0 ms |
||||||||||||
Inverter to Bypass |
4 ms |
0 ms |
||||||||||||
Waveform (Batt. Mode) |
Pure Sine Wave |
|||||||||||||
EFFICIENCY |
||||||||||||||
AC Mode |
87% |
90% |
> 89% |
> 90% |
||||||||||
Battery Mode |
83% |
87% |
89% |
> 88% |
> 89% |
|||||||||
BATTERY |
||||||||||||||
Battery Type |
12 V / 7 AH |
Depending on applications |
||||||||||||
Battery Numbers |
3 |
Depending on applications |
||||||||||||
Recharge Time |
4 hours recover to 90% capacity |
Depending on applications |
||||||||||||
Charging Current |
1.0 A (max.) |
1.0A/2.0A/4.0A/6.0 A ±10% |
||||||||||||
Charging Voltage |
41.0VDC ± 1% |
82.1 VDC ±1% |
218.4 VDC ±1% |
|||||||||||
ENVIRONMENT |
||||||||||||||
Operation Temperature |
0 ~ 40°C (battery life cycle will be shorten when temperature is above 25°C) |
|||||||||||||
Operation Humidity |
<95 % and non-condensing |
|||||||||||||
Operation Altitude |
<1000m |
|||||||||||||
Noise Level |
Less than 50dBA @ 1 Meter |
Less than 55dB @ 1 Meter |
Less than 58dB @ 1 Meter |
|||||||||||
MANAGEMENT |
||||||||||||||
Smart RS-232 or USB |
Windows® 2000/2003/XP/Vista/2008,Windows® 7/8,Linux,Unix,MAC |
|||||||||||||
Optional SNMP |
Power management from SNMP manager and web browser |
* Remarks:Products specifications are subject to change without notice.
Applied Scope
Warranty
One year warranty after the date of delivery.
Payment Terms
Terms of payment is T/T or L/C. 30% deposit before production, 70% balance before shipment.
FAQ
1.Can I support Air-Conditioning on my UPS? |
Air-Conditioning can be considered as a “dirty” load due to continual switching causing voltage and current spikes and surges. The UPS module can cater for a certain level of overload for a small duration, however the duration and level of current surges typically associated with A/C units is far greater than the UPS’ capability. Therefore it is advised not to support the AC on a UPS and supply this element with a generator only if possible. If there is no option but to support the AC using a UPS, it is normal to oversize the inverter by 4-5 times to ensure that the unit will cater for this more demanding load and eliminate any risk to the critical load. Another sensible approach to reduce any risk is toeth critical load is to have a seperate dedicated UPS for the A/C requirement. |
2.Why choose 'Transformer-based' or 'Transformer-less' UPS? |
Transformer based Traditional technology, typically available from 10 kVA, suitable for industrial applications, galvanic isolation with inverter output transformer, typically standard technology from 100 kVA upwards Transformer-less Typical technology from the smallest ratings up to 120 kVA, more compact footprints, lower weights, more suited to IT applications and environments, high efficiency across the load range, generally more cost effective. |
3.Can I add more UPS modules to the system when my load increases? |
Yes, our SU, HM and HT ranges employ a plug and play parallel system that allows additional units to be added to an existing system at a later date. Additional UPS units can be added to either provide redundancy or extra capacity if the load increases. Sometimes it’s worth investing in additional switchgear early on so that more units can be accommodated much more easily. |
4.Why do you need a UPS? |
An Uninterruptible Power Supply (UPS) is used to protect critical loads from mains supply problems, including spikes, voltage dips, fluctuations and complete power failures using a dedicated battery. A UPS system can also be used to ‘bridge the gap’whilst a standby generator is started and synchronised. |
5.Considerations when choosing a UPS and Generator combination? |
It is usually beneficial to deal with one supplier for both items as this eliminates the potential conflict if the equipment does not work well together. Typical problems are related to input harmonics, load acceptance, poor frequency regulation, voltage intolerance and poor response times. |
6.What is ECO mode? |
ECO mode is often referred to as 'Active Standby' and is mainly used on sites where the general mains supply is relatively stable or the load is not senstive to mains interference. The UPS runs in bypass for normal conditions and transfers the load, without break, to inverter when the mains fails. This configuration is available on our entire UPS range upon request. This mode provides an improved system efficiency of around 98%. |
7.Do I have to replace my UPS batteries with the same brand of batteries? |
If you use brand X and need to replace one or two batteries in the string you should use the same brand because they will have the same characteristics. If you need to replace the whole string then you can change brands with fewer risks. |
8.How can I ensure that my UPS batteries are maintained and serviced properly? |
With proper maintenance, battery life can be predicted and replacements scheduled without interrupting your operations. These are IEEE and OEM recommendations for general maintenance: A.Comprehensive maintenance programs with a monthly inspection and more rigorous quarterly and annual checks B.Re-torque all connections, as required C.Load testing D.Cleaning the battery area, as required |
9.How is battery runtime affected if I reduce the load on the UPS? |
The battery runtime will increase if the load is reduced. As a general rule, if you reduce the load by half, you triple the runtime. |
10.If I add more batteries to a UPS can I add more load? |
Adding more batteries to a UPS can increase the battery runtime to support the load. However, adding more batteries to the UPS does not increase the UPS capacity. Be sure your UPS is adequately sized for your load, and then add batteries to fit your runtime needs. |
ONLINE UPS
[Source From: Prostar UPS]
Single Phase / Three Phase Power Supply Online UPS for Communication System
Intelligent AC to DC Integrated Power Supply Online UPS High Frequency and Single Phase
Custom Three Phase Online UPS / 3 phase UPS Low Frequency for Network or Highway lighting
china Solar LED Street Light manufacturer
Solar Powered Street Lights 50 Watt | Integrated Series
IP 65 3000K 4000K Solar LED Street Lights Photovoltaic , Bright Solar Lights
High Power Low Frequency Online UPS IP20 DSP Control For Industrial
Low Frequency Online UPS With Touch Screen Function 10-200KVA
3Phase Low Frequency Online UPS With Isolation Transformer Inside