Online data storage pure sine wave ups 20kva (Centrio DSP 6-20KVA)
Outstanding Feature
1. Advanced Current Control
2. IGBT power component
3. Power Factor Correction
4. Online Maintenance
5. High frequency and double conversion on-line technology
6. Advanced PFC technology
7. EPO Function
8. Wide input voltage range
9. Parallel redundancy
10. Advanced battery management
11. Multilingual LCD display
Technical specification
MODEL
MODEL | C6K(S)L | C10K(S)L | 3C10KSL | 3C15KSL | 3C20KSL |
Power (VA/Watt) |
6000VA/ 4200W |
10000VA/ 7000W |
10000VA/ 7000W |
15000VA/ 10500W |
20000VA/1 4000W |
INPUT
Voltage & Voltage Range | 220 VAC, 1 Phase + Neutral | 220 VAC, 1 Phase + Neutral | 380 VAC, 3 Phase + Neutral | 380 VAC, 3 Phase + Neutral | 380 VAC, 3 Phase + Neutral |
Power Factor | ≥ 0.98 | ≥ 0.98 | ≥ 0.95 | ≥ 0.95 | ≥ 0.95 |
Input Fuse | 32 A NFB | 50 A NFB | 63 A NFB | 100 A NFB | 100 A NFB |
OUTPUT- INVERTER AND BYPASS
Load Power Factor Range | 0.65 inductive - 1.0 resistive | ||||
Voltage Wave Form | Sinusoidal | ||||
Voltage & Voltage Tolerance | 220 / 230 / 240 VAC ± 1% | ||||
Dynamic Response | At 50% - 100 - 50% unbalanced load, max voltage decline < ± 5% |
BATTERY
Type and Placement | Maintenance Free, Dry Type | ||||
Nominal Battery Voltage | 240 VDC |
PROTECTION
Overload | Electronic Protection is available. In case of exceeding limits, the load is transferred to bypass without any interruption | ||||
Short Circuit | Inverter shuts down automatically | ||||
Over Temperature | If the internal Temperature is 90°C the load is transferred to bypass, When it returns < 80°C, Inverter starts to work | ||||
Modem / Network Protection | Modem / Network protection input against to Voltage Spikes |
Dimensions & Weight
Dimensions (mm), W x H x D | 260x717x570 | ||||
Weight W/O / W/Battery (kg) | 35 / 84 | 38 / 93 | 38.5 | 55 | 55 |
* Switch ON/OFF: Press ‘Power on/Alarm Silence’ Key persistently for more than 1 second to turn on the UPS, the output is from inverter. Press ‘Power off’ key persistently for more than 1 second to turn off the UPS.
1) Bypass indicator (Yellow LED)
2) Utility power indicator (Green LED)
3) Inverter indicator (Green LED)
4) Battery indicator (Yellow LED):
5) Fault indicator (Red LED)
6) 2#~6# indicator (2# is Yellow LED, 3#~6# are Green LEDs): these LEDs indicate the load percentage or battery capacity. Under the utility power mode, these LEDs only indicate load percentage. Under the battery mode, these LEDs only indicate battery percentage.
Contact Person: Mr. Song
Tel: 86-137367899
Fax: 86-755-7287468
Single Phase / Three Phase Power Supply Online UPS for Communication System
Intelligent AC to DC Integrated Power Supply Online UPS High Frequency and Single Phase
Custom Three Phase Online UPS / 3 phase UPS Low Frequency for Network or Highway lighting
china Solar LED Street Light manufacturer
Solar Powered Street Lights 50 Watt | Integrated Series
IP 65 3000K 4000K Solar LED Street Lights Photovoltaic , Bright Solar Lights
High Power Low Frequency Online UPS IP20 DSP Control For Industrial
Low Frequency Online UPS With Touch Screen Function 10-200KVA
3Phase Low Frequency Online UPS With Isolation Transformer Inside