Product Details:
Payment & Shipping Terms:
|
Nominal Input Voltage: | 230Vac | Low Line Disconnect: | 184Vac±4% |
---|---|---|---|
High Line Disconnect: | 253Vac±4% | Max AC Input Voltage: | 270Vrms |
Nominal Input Frequency: | 50Hz/ 60Hz (Auto Detection) | Efficiency (Line Mode): | >95% |
Transfer Switch Rating: | 30A | Transfer Time (Ac To Dc): | 20ms (typical) |
Output Voltage Waveform: | Pure Sine Wave | Nominal Output Voltage (V): | 230Vac |
High Light: | solar powered inverter,rack tower ups |
Sine wave Output Solar Power Inverters visual alarm with Circuit breaker:
Key Features:
1. Pure Sine wave Output
2. The charging current is big up to 70 A
3. Output Power Factor is 0.9-1
4. LED display, audible and visual alarm
5. Full automatic and silent operation
6. Rack Tower design
7. Automatically charging
8. Auto change AC-DC
9. Automatically restart
10. Two-steps intelligent charging control to recharging time
Back Panel of Pure Sine Wave UPS Inverter:
ApplicationsSupply the reliable long back up time power for the Home appliances and office appliances (For example:DVD, Fan, TV etc)
Technical Specification of Pure Sine Wave Inverter IG3115 Series:
MODEL |
IG3115E 1000-6000VA |
|||||||||
IG3115E |
IG3115E |
IG3115E |
IG3115E |
IG3115E |
IG3115E |
|||||
Input Voltage Waveform |
Sinusoidal (utility or generator) |
|||||||||
Nominal Input Voltage |
230Vac |
|||||||||
Low Line Disconnect |
184Vac±4% |
|||||||||
High Line Disconnect |
253Vac±4% |
|||||||||
Max AC Input Voltage |
270Vrms |
|||||||||
Nominal Input Frequency |
50Hz/ 60Hz (Auto detection) |
|||||||||
Over-Load Protection (SMPS load) |
Circuit breaker |
|||||||||
Output Short Circuit Protection |
Circuit breaker |
|||||||||
Efficiency (Line Mode) |
>95% |
|||||||||
Transfer Switch Rating |
30A |
|||||||||
Transfer Time (Ac to Dc) |
20ms (typical) |
|||||||||
Output Voltage Waveform |
Pure Sine wave |
|||||||||
Rated Output Power (W) |
1000W |
1000W |
2000W |
2000W |
3000W |
3000W |
||||
Power Factor |
0~1.0 |
|||||||||
Nominal Output Voltage (V) |
230Vac |
|||||||||
Output Voltage Regulation |
±10% rms |
|||||||||
Nominal Efficiency |
>80% |
|||||||||
Nominal DC Input Voltage |
12V |
24V |
12V |
24V |
12V |
24V |
||||
Nominal Charge Current |
70A |
35A |
70A |
35A |
70A |
35A |
||||
Charge Current Regulation |
± 5Adc |
|||||||||
Battery initial voltage |
0-15.7 Vdc (can operate with 0V battery) |
|||||||||
Communication: |
RJ11 (Used for factory testing. No customer interface available) |
|||||||||
Safety Certification |
Compliance with UL458 |
CE(EN60950) |
||||||||
EMI Classification |
FCC, CLASS A |
EN50091-2,CLASS A |
||||||||
Operating Temperature Range |
0°C to 40°C |
|||||||||
Storage temperature |
-15ºC 60ºC |
|||||||||
Operation humidity |
5% to 95% |
|||||||||
Audible Noise |
60dB max |
|||||||||
Cooling |
Forced air, variable speed fan |
|||||||||
Size |
381mm*217mm*179mm |
APPLICATION OF OUR PRODUCT |
1. Living house and home building
2. Office building, factory and warehouse
3. Shopping mall, stadium and so on
4. Power station, field operation and some huge engineer construction
5. suitable for various home appliance, Office equipment,Journeys, Camping, Tents, Boat Trip
WHY CHOOSE US ? |
1, QC Control
The company ranks first in passing the ISO9001 international quality system certification.We established a complete quality system ranging from material source, process, assembling to testing. Most of our products have been certified to meet international safety standards, such as CE (LVD/EMC), CUL,FCC.
2, Best Partner
We have co-operative partner throughout the world including USA, Europe, South America, South Africa, Middle Eastern, India, Turkey, Pakistan, Iran and so on .We offer wide range quality products either from our own standard range or customer-made to your specifications. SORO is becoming the most growthful China UPS supplier all over the world.
COMPANY SHOW |
Introduction of Company
Shenzhen SORO Electronics Co., Ltd is a professional UPS and inverter manufacturer in the field of power electronics for 13 years. We have two large production UPS sites, Zhejiang and Shenzhen. We have own our SMT department. SORO UPS has been a leading enterprise in the UPS industry in China.
Since established, The company has carried out three strategies: operation innovation strategy, people-oriented strategy , technical guidance strategy, and implemented strict scientific management with full-fledged quality management system. The company invests 10% of its annual revenue in researching and development every year. We had international advanced equipments for developing , testing and producing. SORO UPS invited the best technical elites at home, meanwhile, the company established perfect cooperation relationship with domestic scientific research units and academies, to strive for making products that reach advanced world standards.
FAQ |
1. How to choose suitable inverter?
If your load is resistive loads, such as: bulbs, you can choose a modified wave inverter. But if it is inductive loads and capacitive loads, we recommend using pure sine wave power inverter.
For example: fans, precision instruments, air conditioner, fridge, coffee machine, computer, and so on.
Modified wave can be started with some inductive loads, but effect for load using life,because capacitive loads and inductive loads need high quality power
.......................................................................................................................................................................
2. How do I choose the size of the inverter?
Different types of load demand for power are different. You can view the load power values to determine the
size of the power inverter.
Notice:
Resistive load: you can choose the same power as the load.
Capacitive loads: according to the load, you can choose 2-5 times power.
Inductive loads: according to the load, you can choose 4-7 times power.
.......................................................................................................................................................................
3. How connection between batteries and an power inverter?
We usually believe that cables connecting battery terminal to inverter shorter is better. If you are just standard cable should be less than 0.5M, but should correspond to the polarity of the batteries and inverter-side outside. If you want to lengthen the distance between battery and inverter, please contact us and we will calculate the recommended cable size and length. Due to long distances using a cable connection, there will be a reduced voltage, which means that the inverter voltage would be far below the battery terminal voltage, this inverter will appear under voltage alarm conditions
.......................................................................................................................................................................
4. How to calculate the load of working hours requires configuration of the battery size?
We will usually have a formula to calculate, but it is not hundred percent accurate, because there is also the battery's condition, the old batteries have some loss,so this is only a reference value:
Work hours = battery capacity * battery voltage * 0.8/load power (H= AH*V*0.8/W)
.......................................................................................................................................................................
Contact Person: Mr. Song
Tel: 86-137367899
Fax: 86-755-7287468
Single Phase / Three Phase Power Supply Online UPS for Communication System
Intelligent AC to DC Integrated Power Supply Online UPS High Frequency and Single Phase
Custom Three Phase Online UPS / 3 phase UPS Low Frequency for Network or Highway lighting
china Solar LED Street Light manufacturer
Solar Powered Street Lights 50 Watt | Integrated Series
IP 65 3000K 4000K Solar LED Street Lights Photovoltaic , Bright Solar Lights
High Power Low Frequency Online UPS IP20 DSP Control For Industrial
Low Frequency Online UPS With Touch Screen Function 10-200KVA
3Phase Low Frequency Online UPS With Isolation Transformer Inside