Product Details:
Payment & Shipping Terms:
|
| Type: | Online Industrial UPS | Capacity: | 10Kva 8Kw |
|---|---|---|---|
| Wave: | True Sine Wave | Transfer Time: | 0ms |
| Input / Output: | 220Vac | Transformer: | Isolated Transformer |
| Frequency: | 50/60Hz | Application: | Medical Systems |
| Highlight: | Uninterrupted Power Supply |
||
![]()
IA10K Single Phase 10Kva 8KW Low Frequency Online UPS IGBT Technology CPU Control
![]()
1. Computers
2. Home Appliance, such as Fans and lights
3. Office, like computers with Printers
4. Aeronaoutics & Astronautics
5. Electronic & Telecom
6. Army Technology
7. Securities System/ Monitoring / Alarm
8. Sensitive Electronic Equipment
9. Wind Power System
10. Production Equipment
11. Military
12. Medical Systems
13. Network
14. Instrumentation
15. Servers and so on
![]()
![]()
1. On-line UPS
2. DSP system
3.IGBT technology
4.CPU control
5.LCD display
6.Double conversion
![]()
|
Input |
|||||
|
Input voltage |
|||||
|
Rated voltage |
220VAC |
|
|||
|
Phase |
Single phase with ground |
|
|||
|
Turn on voltage range |
220±25% VAC |
|
|||
|
Bypass voltage range |
220VAC±25% |
Phase voltage; Could be adjusted by software.
|
|||
|
Bypass low loss |
165VAC |
||||
|
Bypass low comeback |
Low loss +10VAC |
||||
|
Bypass high loss |
275VAC |
||||
|
Bypass high comeback |
High loss-10VAC |
||||
|
Line low loss/comeback |
(165±5) VAC /(180±5) VAC |
|
|||
|
Line high loss/comeback |
(275±5)VAC/(260±5)VAC |
|
|||
|
Input frequency |
|||||
|
Rated frequency |
50Hz |
Could be adjusted by software. |
|||
|
Frequency low loss |
(40~49)±0.2Hz(default:46Hz) |
||||
|
Frequency low comeback |
Frequency low loss + 0.5Hz |
||||
|
Frequency high loss |
(51~60)±0.2Hz(default:54Hz) |
||||
|
Frequency high comeback |
Frequency high loss - 0.5Hz |
||||
|
Input power factor |
|||||
|
Input power factor |
Max 0.8 |
|
|||
|
Generator |
Support generator input |
Generator rating≥2*UPS rating |
|||
|
Input current |
|||||
|
Rated current |
96A |
|
|||
|
Input protection |
|||||
|
Rated protection |
100A |
|
|||
Output |
|||||
|
Output power |
|||||
|
VA/watt |
10kVA/8kW |
|
|||
|
Rated voltage |
220VAC |
Sine wave |
|||
|
Phase |
Single phase with ground |
|
|||
|
Voltage range |
200/208/220/230/240VAC |
Could be adjusted by software. 10% derating for 208VAC/200VAC. |
|||
|
Voltage regulation |
±2% |
|
|||
|
Voltage distortion |
≤8% |
Full RCD load |
|||
|
≤3% |
Full R load |
||||
|
DC offset |
≤200mV |
|
|||
|
Transient response |
≤9% |
R load 0%~100%~0% |
|||
|
≤6% |
R load 20%~100%~20% |
||||
|
Transient recovery |
≤60ms voltage recovery to 90% |
Full RCD load |
|||
|
Bypass output before turn-on |
Yes |
|
|||
|
Crest ration |
3:1 |
|
|||
|
Output frequency range |
|||||
|
Line mode |
1.Same as input frequency(46Hz~54Hz) |
|
|||
|
2.50Hz(Input frequency>54Hz or Input frequency<46Hz) |
|
||||
|
Battery mode |
(50+0.1) Hz |
|
|||
|
Slew rate |
1 Hz/Sec |
|
|||
|
Efficiency |
|||||
|
Line mode |
> 80% |
R load |
|||
|
Battery mode |
> 85% |
R load |
|||
|
Overload |
|||||
|
line mode/battery mode |
Overload warning only |
105%±5%≤load |
|||
|
2Min,then transfer to bypass and alarm. |
105%±5%<load≤125%±5% |
||||
|
30S,then transfer to bypass and alarm. |
125%±5%<load≤150%±5% |
||||
|
0.5S,then transfer to bypass and alarm. |
load>150%±5% |
||||
|
Automatically recovery |
Yes |
|
|||
|
Short protection |
|||||
|
Line/battery mode |
Cut off output and alarm after 3S |
|
|||
|
Transfer time |
|||||
|
Line to battery mode |
0mS |
|
|||
|
Battery to line mode |
0mS |
|
|||
|
Line to bypass mode |
<4mS |
|
|||
|
Bypass to line mode |
<4mS |
|
|||
Battery and charger |
|||||
|
Battery |
|||||
|
Rated voltage |
192VDC |
|
|||
|
Protection |
|||||
|
Low alarm voltage / comeback voltage |
(180.8V±4V)/ (188.8V±4V) |
|
|||
|
Shutdown voltage |
(176V±4V)/ (184V±4V) |
Watt Value < 1000W |
|||
|
(160V±4V)/ (168V±4V) |
Watt Value ≥ 1000W |
||||
|
Battery protection |
|||||
|
Overcharge protection |
(250V±4V) |
|
|||
|
Battery test |
|||||
|
Battery weak |
Support |
|
|||
|
Battery fault |
Support |
|
|||
|
Charger |
|||||
|
Output voltage |
(220±2)VDC |
Float charge voltage |
|||
|
Charge time |
Determined by battery capacity |
|
|||
|
Charge current |
5A |
|
|||
|
Interface |
|||||
|
Alarm silence |
Support |
|
|||
|
DC power turn-on |
Support |
|
|||
|
Automatically restart |
Support |
|
|||
|
alarm |
|||||
|
Battery mode |
Beep/4s |
|
|||
|
Battery low/charger fault |
Beep/1s |
|
|||
|
UPS fault |
Continuously beep |
|
|||
|
Overload |
Beep/1s |
|
|||
|
Bypass mode |
Beep/2Min |
|
|||
|
Communication |
|||||
|
RS232/ RS485 interface |
Support |
|
|||
|
Output dry contactor |
Support |
|
|||
|
Intelligent slot |
Support |
|
|||
|
Monitor software |
Appending with UPS |
|
|||
|
Cooling |
|||||
|
Force air cooling |
|||||
|
Display |
|||||
|
LCD displays UPS status |
Support |
|
|||
|
Environment |
|||||
|
Work temperature |
0℃~40℃ |
|
|||
|
Altitude |
<1000m |
|
|||
|
Audible noise |
≤55dB |
|
|||
|
Storage temperature |
-15℃~45℃ |
|
|||
|
Work humidity |
20%~95% |
|
|||
|
Standard |
|||||
|
EMS/EMI |
|||||
|
Conducted |
IEC EN62040-02 |
|
|||
|
Radiated |
|
||||
|
Anti-interference |
IEC 61000-4-2.4.5 Level IV, IEC61000-4-3 Level III |
|
|||
|
Safety |
|||||
|
Safety |
GB4943-2001/IEC62040-1 |
|
|||
|
Transportation |
|||||
|
Drop test |
GB-T4857-18 |
|
|||
|
Vibration test |
B-WR1-129(GB-T14715-93) |
|
|||
|
Machinery features |
|||||
|
Connection |
|||||
|
Inlet |
Wiring terminal block |
|
|||
|
Outlet |
Wiring terminal block |
|
|||
|
External battery slot |
Wiring terminal block |
|
|||
|
Size |
|||||
|
UPS net weight and size |
|||||
|
L*W*H(mm) |
560*260*717 |
|
|||
|
Net weight(Kg) |
79.5 |
|
|||
|
UPS weight and package size |
|||||
|
L*W*H(mm) |
620*320*840 |
|
|||
|
weight(Kg) |
92.5 |
|
|||
|
Optional functions |
|||||
|
60Hz |
Support |
Could be set by software |
|||
|
Converter mode |
Support |
Could be set by software |
|||
|
ECO mode |
Support |
Could be set by software |
|||
|
EPO mode |
Support |
Need to increase related components |
|||
More Options:
![]()
![]()
Contact Person: Mr. Song
Tel: 86-137367899
Fax: 86-755-7287468
Single Phase / Three Phase Power Supply Online UPS for Communication System
Intelligent AC to DC Integrated Power Supply Online UPS High Frequency and Single Phase
Custom Three Phase Online UPS / 3 phase UPS Low Frequency for Network or Highway lighting
china Solar LED Street Light manufacturer
Solar Powered Street Lights 50 Watt | Integrated Series
IP 65 3000K 4000K Solar LED Street Lights Photovoltaic , Bright Solar Lights
High Power Low Frequency Online UPS IP20 DSP Control For Industrial
Low Frequency Online UPS With Touch Screen Function 10-200KVA
3Phase Low Frequency Online UPS With Isolation Transformer Inside